bSens.INR
Coagulation · PT/INR
Point-of-care strip test that uses graphene to measure prothrombin time, expressed as the PT/INR value (International Normalized Ratio).
The reagent strip
Each test is a bSens strip configured for what it measures or detects. For bSens.INR, that is clotting time.

Biomarker: What the drop reveals. For bSens.INR, clotting time.
Reagent: The chemistry on the strip that reacts with the sample.
Electrode: The sensor printed on the strip that turns the reaction into a signal.
Strip: The reagent strip, which carries the reagent and the electrode, receives the drop and goes into the analyzer.
The same analyzer and the same architecture are designed to grow from INR to other tests.
TRL, or technology readiness level, is a scale from 1 to 9 that shows a technology's stage of development. It does not indicate how a test performs.
Coagulation · PT/INR
Point-of-care strip test that uses graphene to measure prothrombin time, expressed as the PT/INR value (International Normalized Ratio).
Lactate
A graphene-based strip test for measuring lactate at the point of care, planned for the same bSens One analyzer and architecture.
Syphilis
A point-of-care strip test with nanoparticles, in development for syphilis.
Spinal muscular atrophy (SMA)
A point-of-care strip test with single-domain antibodies, in development for spinal muscular atrophy.
Carbapenem-resistant bacteria
A point-of-care strip test with CRISPR, in development for carbapenem-resistant bacteria.
Standard electrochemical sensor
Standard electrochemical sensor strips for assay development.
For research use only. Not for use in diagnostic procedures.
Scientific context
Data from scientific papers and books. They describe the condition, the field and the technology, not bSens products.
Electrical signal
In an electrochemical biosensor, a biological component recognizes the substance being measured. That recognition produces an electrical signal, proportional to its concentration, which a transducer monitors. 1
Glucose
Commercial screen-printed strips for glucose self-monitoring appeared in the 1980s. By 2010, most point-of-care glucose biosensors used disposable strips with screen-printed enzyme electrodes. 2
Disposable
Screen-printed electrodes are single-use devices and can be mass-produced with reproducible surfaces. The production of these reproducible, disposable electrodes has had a profound impact on the development of electrochemical biosensors. 3,4
High conductivity
In graphene, the high surface-to-volume ratio allows more recognition molecules to be attached, and the high conductivity supports sensitive electrical and electrochemical read-outs. 5
Electrochemical detection
Among graphene-based biosensors described in the literature, electrochemical detection is the most common. 6
Limited data
A 2018 review of graphene biosensors notes that, because nanomaterial-based sensor designs were recent, there were no detailed reports of accuracy, precision, or positive and negative predictive values. The authors ask future studies to take these parameters into account. 6